КВБШвнг(А)-LS
Retard flame spread from bunched cables
Low gas and fume emission
Braided armor of steel galvanized tapes
designed for cold climates
Документация кабеля
Marking decoding
- — Control cable
- — PVC compound insulation
- — Armor of steel galvanized tapes
- — Extruded PVC protective hose
- — Retard flame spread from bunched cables
- — Reaction to fire class A
- — Low gas and fume emission
Specifications
Rated AC voltage | 0,66/1 kV |
Rated frequency | 50 Hz |
Minimum bending radius allowed for single-strand round conductor | 10 cable diameters |
Minimum bending radius allowed for multi-strand round conductor | 10 cable diameters |
Maximum pulling tension should not exceed | 50 N/mm²td> |
Reaction to fire class | O1.8.2.5.4 |
Operational life | 30 years |
Shelf life | 5 years |
Operating ambient temperatures | from -50°C to +50°C |
Resistance to high relative atmospheric humidity at ambient temperature up to +35°C | 98% |
Installation without preheating is permitted at temperature not lower than: | -15°С |
Cable design

- Copper conductor
- PVC compound insulation
- PVC extruded cushion filling the interstices between the insulated conductors to make a round shaped cable
- Armor of steel galvanized tapes
- PVC compound sheath
Conductor coding
- Color coding using a counting pair in each layer is applied. The counting pair conductors must be of different colors and must differ from the colors of other conductors. Each separate layer must have one conductor of red colour and one of blue. These two are placed side by side and called a counting pair. Other conductors must be white. The blue conductor is used to find the required one by counting from it. The red conductor is used to determine the direction of counting.
- The digital code is applied by printing. The colour of the digits must contrast with the main colour of the conductors insulation. The bottom of the digit must be underlined. The counting starts from 1, each conductor has a unique number.
Application
- This cable type is used for transmission and distribution of power in electric installations with rated alternating voltage of 660 V or 1000 V and 50 Hz frequency. .
- Its laying has no restrictions of the difference in elevation along the cable route including its vertical sections.
- The cable is intended to operate in electric networks of alternating voltage with grounded or isolated neutral. Their time of operating in single-phase earth fault mode should not exceed 8 hours and the total operating time in single-phase earth fault mode does not exceed 125 hours per year.
- These cables are designed for laying of single cable lines in the cable installations and industrial premises. Bunched laying is allowed only in the outdoor electrical installations and industrial premises with just occasional presence of the maintenance staff. In that case a passive fire protection is required.
Cross-sections and macro dimensions
4
5
7
10
14
19
4
5
7
10
14
19
4
5
7
10
14
19
27
37
7
7
10
4
5
7
10
14
19
27
37
4
5
7
10
14
19
27
37
4
5
7
10
14
19
27
37
GOST R:
GOST R 1508-78
Active
GOST R 26411-85
Active
GOST R 22483-2012
Active
GOST R 23286-78
Active
Cables, wires and cords. Standards for insulation and sheath thickness and voltage test
since 01.01.1983
GOST R 7006-72
Active
GOST R 31565-2012
Active
GOST R 15150-69
Active
Machines, instruments and other industrial products. Modifications for different climatic regions. Categories, operating, storage and transportation conditions as to environment climatic aspects
since 01.01.1971
Часто задаваемые вопросы
Frequently asked Questions
- How much do the VOLTA® cables and wires cost?
- What products are there in stock?
- What are the payment terms?
- What time does it take to execute an order?
- What are the delivery options?
- Can I get a 10-20 cm cable sample to make a decision about a purchase?
- Can I get technical advice from PC SEC experts?